show module 1 detail Output
Getting details from the Service Module, please wait…
Unable to read details from slot 1
ASA 5500 Series Security Services Module-10
Model: ASA-SSM-10
Hardware version: 1.0
Serial Number: 12345678
Firmware version: 1.0(7)2
Software version:
Status: Init
The Status field displays the current status of the module and can have the following states:
■ Initializing—The module has been recognized and is in the process of being initialized
with the system.
■ Up—The module is online and functioning properly.
■ Unresponsive—The Security Appliance cannot communicate with the module.
■ Reloading—The module is reloading.
■ Shutting—The module is in the process of shutting down.
■ ShuttingDown—The module has completed the shutdown procedures and is offline.
■ Recover—The module is attempting to download a recovery image.
In Example 19-8, you will notice that the software version is not displayed. The reason is
that the AIP-SSM cannot read the IPS image due to corruption or nonexistence. To resolve
this, the AIP-SSM module requires a new IPS image from which to initialize. The Security
Appliance uses the hw-module module 1 recover command to define where to download an
IPS image file from a TFTP server. To manually specify the TFTP server, filename, and
Example 19-8 show module 1 detail Output
Getting details from the Service Module, please wait…
Unable to read details from slot 1
ASA 5500 Series Security Services Module-10
Model: ASA-SSM-10
Hardware version: 1.0
Serial Number: 12345678
Firmware version: 1.0(7)2
Software version:
Status: Init
612 Chapter 19: IPS and Advanced Protocol Handling
network configurations, you can add the configure keyword to the preceding command, as
shown in Example 19-9.